Skip to main content

Explainer · 2 min 54 s

904L stainless steel pipe acid service: four conditions

904L stainless steel pipe in acid service is one grade and four published conditions: the acid's character, its concentration, its temperature and the rest o…

Format
Explainer
Published
Duration
2 min 54 sec
Language
English
Full explainer series: Junda Explainers

About this video

This explainer is educational. It explains the published limits and the order fields for the topic; confirm the grade, standard, size, condition, inspection and documents with Junda for each order.

Chapters

Each chapter opens the video at that point on YouTube.

  1. 0:00

    904L stainless steel pipe acid service: four conditions

    904L stainless steel pipe in acid service is one line on the purchase order. Junda's published page puts the same grade at 98 percent sulphuric acid, and at 1 to 2 percent hydrochloric.

  2. 0:14

    Why 904L stainless steel pipe is used in acid service

    904L is a super austenitic: nickel 24 to 26 percent, chromium 19 to 21. Molybdenum 4 to 5 percent, and copper 1 to 2 percent. Copper is the addition acid duty asks for. The acid touches one face only: the bore. The wall behind it carries the pressure and the corrosion. That wall is quoted in one condition: solution annealed at 1100 to 1150 degrees, then a rapid cool. The published minima are 490 megapascals tensile, 215 yield, and 35 percent elongation.

  3. 0:59

    904L acid limits: sulphuric, phosphoric and hydrochloric

    Concentration, as the page states it. Pure sulphuric acid: 0 to 98 percent, and up to 40 degrees. Pure phosphoric acid: 0 to 85 percent. Hydrochloric acid: 1 to 2 percent. The same grade, the same page. And say whether the concentration is by weight or by volume. The character of the acid decides which way the wall goes. Copper keeps 904L passive in a reducing acid. In strongly oxidizing nitric acid, the published page puts 904L below high-alloy steels without molybdenum. Then the states the page does not cover. After a shutdown, liquid and deposits stay on that wall. In wet-process phosphoric acid, the same page says impurities strongly affect the resistance.

  4. 1:51

    904L temperature, impurities and shutdown conditions

    An order usually states one exposure: the normal process. That is one row of five. Startup and dilution can differ from steady running. Cleaning is a separate chemical exposure. Shutdown leaves liquid and deposits standing. And an upset condition sets the boundary of the choice.

  5. 2:10

    What the mill certificate covers in acid service

    What does the mill sign? Chemistry and condition, on an EN 10204 3.1 certificate, as agreed. The product standard names the pipe: A312, A213, A269 or A376. It does not sign off your process. So the compatibility review stays with you, and it goes into the enquiry. So write four conditions, not one word. The acid, and its character. Concentration, and the basis it is stated in. Temperature, with the states around it. And the impurities, the flow and the shutdown. Send the exposure, the temperature and the size, and we confirm the pipe against your conditions.

Specify the pipe or tube for your project

Send the grade, standard, OD × wall × length, wall basis, quantity, inspection and documents with your enquiry.