Explainer · 2 min 37 s
Heat exchanger tube specification: 3 forms, 3 drawings
A heat exchanger tube specification is three different documents: straight tube, U-bend tube and rectangular profile each need a different drawing, and the m…
- Format
- Explainer
- Published
- Duration
- 2 min 37 sec
- Language
- English
About this video
This explainer is educational. It explains the published limits and the order fields for the topic; confirm the grade, standard, size, condition, inspection and documents with Junda for each order.
Chapters
Each chapter opens the video at that point on YouTube.
- 0:00
Heat exchanger tube specification: straight, U-bend, rectangular
A heat exchanger tube specification is not one document. Straight, U-bend or rectangular: the form decides what the drawing has to say, and the mill cannot invent the rest.
- 0:12
Straight, U-bend or rectangular heat exchanger tube
The bundle decides the form before the grade does. Straight tube is a cut length: diameter, wall basis, length, and the end condition. U-bend is a hairpin: bend radius, centre distance, leg lengths, and the dimensions after bending. Rectangular is a non-round passage, and its drawing starts with the profile. In a shell-and-tube exchanger, every tube passes through a tube sheet. Three forms, one fit: the drawing is what makes the bundle go together.
- 0:44
U-tube drawing: bend radius, centre distance, leg length
A U-tube is two straight legs joined by a hundred-and-eighty-degree bend. The drawing fixes the bend radius, the centre distance between the legs, and the leg length. Change the radius and the centre distance moves with it. Bending stretches the outside of the bend and thins the wall there. The published formula is D over four R plus two D. At R one hundred it takes five point six percent. At R forty, twelve. In the mill the bend is cold formed, then heat treated when the radius is tight. A ball gauge goes through the bore, and the tube is hydrotested after forming.
- 1:22
Rectangular heat transfer tube and hydraulic diameter
A rectangular heat transfer tube is a non-round passage. The drawing carries the outside profile, the wall, the corner radius, and the flow dimension. Corner radius is the one that gets left off the enquiry. For a non-round passage, the flow is sized by the hydraulic diameter. Four times the flow area, divided by the wetted perimeter. A twenty by ten passage is two hundred square millimetres over sixty of perimeter: thirteen point three.
- 1:52
Heat exchanger tube standard, wall basis and enquiry line
The standard names the wall basis, and the wall basis is what you pay for. A213 makes minimum wall the default. A269 works on nominal wall. A312 is process piping, not exchanger tubing. A1016 carries the tests behind both. So the enquiry carries the form, the standard, and the drawing. For a U-bend that means the bend schedule: a radius for each row, the leg lengths, and which dimension they are. For a profile, the outside and inside profile, the corner radius, and the wall. Then the tests, the straightness limit, and the documents. Send the form, the drawing and the standard, and we confirm the tube against them.
Specify the pipe or tube for your project
Send the grade, standard, OD × wall × length, wall basis, quantity, inspection and documents with your enquiry.