Skip to main content

Explainer · 3 min 5 s

Pipe weight per metre: the formula and the three numbers

How the wall, the grade and the length set a seamless pipe's mass per metre, worked through at DN 150 in 316L and 2507, to a 6 m length and a U-bend.

Format
Explainer
Published
Duration
3 min 5 sec
Language
English
Full explainer series: Junda Explainers

About this video

This explainer is educational. Every mass is theoretical: it uses the grade's nominal density and the nominal wall, not a weighed length. The density on the mill certificate, the wall as measured and the length as cut decide what the scale reads. Dimensions, standard and inspection scope are confirmed in the quotation.

Chapters

Each chapter opens the video at that point on YouTube.

  1. 0:00

    Pipe weight per metre: the formula and the three numbers

    Pipe weight per metre is one formula, and it starts with the wall. Same DN 150 pipe, same 316L: 14.09 kilograms a metre in 10S, 28.80 in 40S.

  2. 0:14

    Pipe weight per metre: why the wall decides it

    Cut the pipe and the wall is a ring. Unroll that ring and it becomes a strip 518 millimetres wide. So the steel in one metre is pi times wall times outside diameter minus wall.

  3. 0:28

    How to calculate pipe weight per metre from outside diameter and wall

    Multiply that area by density and the mass per metre falls out. Wall, times outside diameter minus wall, times density, times pi over one thousand. DN 150 in 10S, 316L: 14.09 kilograms a metre. In 40S it is 28.80, because the wall more than doubles. The wall is the lever. Density is a small correction. Add half a millimetre to the wall and the pipe gains two kilograms a metre. Change the grade from 316L to 2507 and it loses 0.35. Same size, same wall. The wall moves the mass nearly six times more.

  4. 1:10

    Stainless steel density by grade: 304L, 316L, 2205, 2507, C-276

    Density belongs to the grade. Junda publishes 7.93 for 304L, 8.00 for 316L, 7.85 for 2205 and 7.80 for 2507. C-276 is 8.89. Two pipes of one size can differ before the wall is measured. Same outside diameter, same wall. 316L gives 14.09 kilograms a metre. In 2507 it is 13.74, because 7.80 over 8.00 is 97.5 percent. Two and a half percent lighter, on the same size.

  5. 1:53

    From kg per metre to a 6 metre length and a U-bend

    Weight per metre is not the weight on the truck. A six-metre length of that DN 150 pipe is 84.55 kilograms. A hundred lengths is 8,455 kilograms, and that is the number the freight quote reads. A straight length is the easy case. A U-bend is weighed on its developed length. Two legs of 3,000 millimetres and a 100 millimetre bend radius give 6,314 millimetres. That is 88.97 kilograms, not the 84.55 the legs alone suggest.

  6. 2:30

    Theoretical mass or weighed mass: what the documents decide

    The formula gives a theoretical mass. Three documents decide the rest. The density on the mill certificate, or in the ordered specification, not the nominal table. The inspection report carries the wall that was measured. The packing list carries the length that was cut. So the mass question is a size question. Grade and UNS, then outside diameter and wall, with the basis. Length and quantity, then the standard and the inspection scope. Send the grade, the outside diameter, the wall and the length, and we confirm the mass against the documents.

Specify the pipe or tube for your project

Send the grade, standard, OD × wall × length, wall basis, quantity, inspection and documents with your enquiry.