Explainer · 2 min 38 s
UT, ET and Hydrostatic Testing: Three Different Questions
UT, ET and hydrostatic testing answer three different questions: ultrasonic testing reads the wall volume, eddy current testing reads the surface and the lay…
- Format
- Explainer
- Published
- Duration
- 2 min 38 sec
- Language
- English
About this video
This explainer is educational. It explains the published limits and the order fields for the topic; confirm the grade, standard, size, condition, inspection and documents with Junda for each order.
Chapters
Each chapter opens the video at that point on YouTube.
- 0:00
UT, ET and hydrostatic testing: three different questions
A pipe can pass one inspection and still fail the next. UT, ET and hydrostatic testing each answer a different question. Here is what each test can see. Start with the question, not the test name. Ultrasound sends a pulse through the wall and reads the echo. Eddy current reads the surface, and a shallow layer below it. The hydrostatic test fills the pipe and loads the whole wall.
- 0:26
What an ultrasonic and eddy current test can see in a stainless pipe
All three tests meet at the same wall. Sound crosses it, eddy currents skim it, and pressure pushes it out. Junda's published range runs from six to six hundred and thirty millimetres outside diameter, and from zero point two to eighty millimetres of wall. That is a manufacturing range, not a stock list for every grade. An eddy current coil never touches the pipe. Its alternating field drives currents in the surface, and a defect changes the signal. So the method reads the surface and a thin layer below it, not the middle of the wall. Inspection is one of the seven published steps, after cutting. The dual system scans the whole length. A discontinuity marks the trace, surface or mid-wall.
- 1:11
What a hydrostatic test proves: pressure tightness and hoop stress
Now the pressure test. Water fills the bore. The pump holds it, and the wall carries the load. A through-wall defect shows here as a leak. Detection looks for a defect. This test proves the pipe holds. Hoop stress is the number behind that test. Stress rises with pressure and diameter, and falls as the wall gets thicker. Barlow writes it as sigma equals pressure times diameter, over twice the wall. The design code turns it into the required wall, with allowances on top.
- 1:43
What a mill test certificate and a UT/ET system prove
Junda publishes one fully automated UT and ET system. It scans the length for internal and surface defects. The published testing centre lists five intermediate UT inspectors. The result travels on paper: an EN 10204 3.1 mill test certificate, as agreed in the order. Third-party inspection to 3.2 is arranged when the order names it. Junda publishes seven test groups, and not every shipment receives every one.
- 2:14
How to specify UT, ET and hydrostatic testing in a pipe enquiry
So write the inspection question into the order. Method, and the standard edition it follows. Coverage, and the acceptance criteria. Whether the hydrostatic test is required, at what pressure and for how long. Junda confirms the scope and the documents in the quotation. Send Junda the grade, size, quantity and the inspection scope you need.
Specify the pipe or tube for your project
Send the grade, standard, OD × wall × length, wall basis, quantity, inspection and documents with your enquiry.