Explainer · 2 min 37 s
Hastelloy C-276 pipe corrosion data: how to read it
Hastelloy C-276 pipe corrosion data is a specimen in one bath at one concentration and one temperature: 0.1 mm a year is the line, and twenty years on that l…
- Format
- Explainer
- Published
- Duration
- 2 min 37 sec
- Language
- English
About this video
This explainer is educational. It explains the published limits and the order fields for the topic; confirm the grade, standard, size, condition, inspection and documents with Junda for each order.
Chapters
Each chapter opens the video at that point on YouTube.
- 0:00
Hastelloy C-276 pipe corrosion data: how to read it
Hastelloy C-276 pipe corrosion data starts at one tenth of a millimetre a year. That line is measured in a bath like this one, not on your line.
- 0:10
What a C-276 corrosion test measures: the 0.1 mm a year line
A corrosion rate comes from a specimen in a bath. Here: hydrochloric acid at twenty percent, boiling, and the line at one tenth of a millimetre a year. Add ferric ions, air or solids, and this is no longer the test. One tenth of a millimetre a year is two millimetres in twenty years. The chart measures the rate. Your design life sets the years. So the wall is where a reading becomes a decision.
- 0:36
C-276 chemistry and PREN: molybdenum, tungsten, chromium
C-276 holds molybdenum at fifteen to seventeen percent. Tungsten adds three to four and a half, and chromium sits at fourteen and a half to sixteen and a half. Carbon is held at one hundredth of a percent or less. The resistance number is chromium plus three point three times molybdenum. C-276 has no nitrogen in the published table, so there is no nitrogen term. At the minimum that is sixty-four, at the midpoint sixty-eight, at the maximum seventy-three.
- 1:08
Where C-276 works, and the conditions the chart leaves out
Junda's published pages list C-276 for sulfuric acid condensers and acetic acid reactors. There the wall is a tube: process inside, cooling water outside. The data is about that wall, and only that wall. In a line the medium keeps moving. Solids at velocity strip the film and turn corrosion into erosion. Aeration in hydrochloric acid shifts the potential and attack accelerates. Trace ferric or cupric ions do the same, with no warning on the chart. Junda's published route runs from cold rolling to inspection in seven steps. For C-276 the anneal is at least eleven hundred and twenty-one degrees Celsius, then a water quench. Seamless pipe to ASTM B622 carries no longitudinal weld to sensitise.
- 2:00
How to order C-276 pipe: ASTM B622, solution anneal, documents
The purchase description names ASTM B622 for seamless pipe. It names solution heat treatment and hydrostatic testing. And it names the document: an EN 10204 3.1 inspection certificate, agreed per order. Grade and UNS number, standard, size and schedule. Heat treatment, tests and the document go on the same line item. Then send the exposure: acid, concentration, temperature and impurities. Send the exposure with the grade; the quotation confirms the rest.
Specify the pipe or tube for your project
Send the grade, standard, OD × wall × length, wall basis, quantity, inspection and documents with your enquiry.